Quadra-Fire QV-PIER Spécifications

Naviguer en ligne ou télécharger Spécifications pour Foyers Quadra-Fire QV-PIER. Quadra-Fire QV-PIER Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 37
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Models:
QV-ST
QV-PIER
Installers Guide
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
Underwriters
Laboratories Listed
297-900F 7/03
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
QV-PIER
QV-ST
Please contact your Quadra-Fire dealer with
any questions or concerns. For the number of
your nearest Quadra-Fire dealer, please call
1-800-234-2508
Printed in U.S.A. Copyright 2003
Quadra-Fire, a brand of Hearth & Home Technologies Inc.
1445 N. Hwy. 395, Colville, WA 99114
Vue de la page 0
1 2 3 4 5 6 ... 36 37

Résumé du contenu

Page 1 - Installers Guide

1- Do not store or use gasoline or other flam-mable vapors and liquids in the vicinity of thisor any other appliance.- What to do if you smell gas• D

Page 2

10Figure 1. Diagram of the QV-PIERELECTRICALACCESSGAS LINEACCESSREARCOLLARSGAS CONTROLS& LABELSBOTTOMGRILLESIDE GLASSDOOREND GLASSDOORTOP STANDOFF

Page 3

11Figure 2. Diagram of the QV-STLEFT SIDEFRONTRIGHT SIDETOP VENT COLLARSREAR VENTCOLLARSELECTRICALACCESSGAS LINEACCESSGAS CONTROLS& LABELSBOTTOM G

Page 4 - Service Parts

12Installing the FireplaceStep 1. Locating the FireplaceThe diagram below shows space and clearance require-ments for locating a fireplace withi

Page 5

13Framing should beconstructed of 2 X 4lumber or heavier.Model A B C D EVENTED VENTEDTOP REARQV-ST

Page 6

14NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOINT.Figure 5.D-Series Direct Vent Component Specifications (5-inch inner pipe / 8 5/8-inch o

Page 7

15Figure 6. Vent System Components and Termination KitsStep 3. Installing the Vent SystemA. Vent System ApprovalsThese models are approved to use D-

Page 8 - Approvals and

16Figure 7.Straight Up Vertical VentingSTRAIGHT UPVERTICAL VENTINGV (FT.)40' MAX. (12.4 M)STRAIGHT OUTHORIZONTAL VENTINGHMax. Run24" (610 mm

Page 9 - Getting Started

17VENTING WITH ONE (1) 90° ELBOW V (FT.) H (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.86m)

Page 10

18VENTING WITH TWO (2) 90° ELBOWS V (FT.) H + H1 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.8

Page 11

19VENTING WITH TWO (2) 90° ELBOWSV H H + H11' MIN. (305 mm) 2' MAX. (610 mm) 3' MAX. (914 mm)2' MIN. (610 mm) 4' MAX. (1.22

Page 12 - Installing the Fireplace

2These units MUST use one of the vent systemsdescribed in the Installing the Fireplace section ofthe Installers Guide. NO OTHER vent systems orcompone

Page 13

20Figure 14. Venting with three 90° elbowsVENTING WITH THREE (3) 90° ELBOWS1' MIN. (305 mm) 2' MAX. (610 mm) 3' MAX. (914 mm)2'

Page 14

21VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.)1' MIN. (305mm) 3' MAX. (914mm)2' MIN. (610mm) 6' MAX. (1.86m)3'

Page 15 - Identifying Vent Components

22!WARNING: ENSURE THAT THE FIBER-GLASS ROPE GASKET SUPPLIED WITHTHE FIREPLACE SEALS BETWEEN THEFIRST VENT COMPONENT AND THE OUTERFIREPLACE WRAP.If th

Page 16

23For Vertical Runs - The vent system must be supportedevery eight (8) feet (2.4m) above the fireplace flue outlet bywall brackets (See Figure 19).To

Page 17

24For Vertical Runs - One ceiling firestop is REQUIRED atthe hole in each ceiling through which the vent passes.To install firestops for vertical runs

Page 18 - + H = 37' MAX. (11.3m)

25!C. Vent TerminationFor Horizontal Terminations - To attach and secure thetermination to the last section of horizontal vent:• Rotate and interlock

Page 19 - V FT. H + H

26uV= VENT TERMINALX= AIR SUPPLY INLET= AREA WHERE TERMINAL IS NOT PERMITTED Figure 26. Vent Termination Minimum ClearancesA = 12" ...

Page 20 - V H H + H

27For Vertical Terminations - To locate the vent and installthe vent sections:• Locate and mark the vent centerpoint on the undersideof the roof, and

Page 21 - + H + H

28Figure 30. Gas Supply Line• Insert insulation from the outside of the fireplace andpack the insulation tightly to totally seal between thepipe and

Page 22 - Venting Out Top

29Step 8. Wiring the FireplaceNOTE: Electrical wiring must be installed by a licensedelectrician.CAUTION: DISCONNECT REMOTE CONTROLS IF AB-SENT FOR E

Page 23

3TABLE OF CONTENTSSafety and Warning Information ... 2Service Parts Lists...

Page 24 - NAILS (4 REQUIRED)

30Step 9. FinishingFigure 33 shows the minimum vertical and correspondingmaximum horizontal dimensions of fireplace mantels or othercombustible proje

Page 25 - 7 1/4"

31Installing the TrimCombustible materials may be brought up to the specifiedclearances on the side and top front edges of the fireplace,but MUST NEVE

Page 26 - (See Note 5)

32Step 11. Lighting the ApplianceSTANDING PILOT IGNITIONA. This appliance (standing pilot version) has a pilotthat must be lighted by hand. When lig

Page 27 - NAILING TABS

33Step 12. Before Lighting the FireplaceBefore lighting the fireplace, be sure to do the following:Remove all paperwork from underneath the fireplac

Page 28 - 3/8” (10mm)

34Maintaining and Servicing Your FireplaceFireplace MaintenanceAlthough the frequency of your fireplace servicing and main-tenance will depend on use

Page 29

35TroubleshootingWith proper installation, operation, and maintenance your gas fireplace willprovide years of trouble-free service. If you do experie

Page 30 - 12"

36Symptom Possible Cause Corrective Action3. (Continued) f. High limit switch is defective orhas reached its maximumtemperature.Allow the unit to cool

Page 31

37Lifetime WarrantyLIMITED LIFETIME WARRANTYThe Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will

Page 32

4QV-PIER (NG, LP) Exploded Parts Diagram / Vue éclatée des pièces* Part number list on following page.* La liste des numéros de pièce se trouve

Page 33 - After the Installation

5QV-PIER Exploded Parts Diagram / Vue éclatée des piècesITEM /PIÈCECOMMON PARTS / PIÈCES COMMUNESSERIAL # / N° DE SÉRIEPART NUMBER/ N° DE PIÈCEON/

Page 34 - Fireplace Maintenance

6QV-ST (NG, LP) Exploded Parts Diagram / Vue éclatée des pièces* Part number list on following page.* La liste des numéros de pièce se trouve à

Page 35 - Troubleshooting

7QV-ST Exploded Parts Diagram / Vue éclatée des piècesITEM /PIÈCECOMMON PARTS / PIÈCES COMMUNESSERIAL # / N° DE SÉRIEPART NUMBER/ N° DE PIÈCEON/OFF

Page 36 - Troubleshooting (continued)

8Appliance CertificationThe Quadra-Fire models discussed in this Installers Guidehave been tested to certification standards and listed bythe applicab

Page 37 - Lifetime Warranty

9Getting StartedIntroducing the Quadra-Fire Gas FireplacesQuadra-Fire direct vent gas fireplaces are designed to op-erate with all combustion air siph