7051-158B
December 6, 2011
R
EDGE 60 Pellet Fireplace
CAUTION! SHOCK AND SMOKE HAZARD!
• Proper Shutdown Procedure must be followed.
• Smoke spillage into room can occur if appliance is not
cool before turning off power switch.
• Risk of shock if appliance is not turned off before servic-
ing appliance.
A. Proper Shutdown Procedure
Set wall control to OFF on AUTOMATIC / MANUAL SET-
TING screen. Figure 14.1.
Wall control screen will scroll through the following mes-
sages after setting to OFF.
• Shutdown
• Auto-Clean
• Off
Before Servicing Your Appliance
Manual
Off
Automatic
Figure 14.1
3
Maintaining & Servicing Your Appliance
B. Quick Reference Maintenance Chart
NOTICE: These are recommendations. Clean more frequently if you encounter heavy
build-up of ash at the recommended interval or you see soot coming from the
vent. Not properly cleaning your appliance on a regular basis will void your
warranty.
Approximately 45 minutes after setting the wall control to
OFF, the appliance should be cool enough to touch. If so,
now you can turn the power switch to OFF and pull the
appliance foward on the rails.
There is an interlock switch next to the power switch that as
you slide the appliance out it will ensure the auto-clean system
and the auger will not run, but the blowers will operate.
After servicing, restart with the AUTO/MANUAL SETTINGS
screen. Figure 14.1.
Follow the detailed instructions found in this
section for each step listed in the chart below.
Cleaning or Inspection
Frequency Daily Weekly Every 2
Weeks
Monthly Yearly
Ash Pan - Burning Wood Pellets Every 5 bags of fuel OR X
Ash Pan - Burning Alternate Fuels Every 1 bag of fuel OR X
Ash Removal from Firebox More frequently depending on the
fuel type or ash build-up
OR X
Auto-Clean Inspection More frequently depending on the
fuel type
OR X
Blower, Combustion (Exhaust) More frequently depending on the
fuel type
OR X
Blower, Convection More frequently depending on the
operating environment
OR X
Door Latch Inspection Prior to heating season OR X
Firebox - Prepare for Non-Burn Season At end of heating season OR X
Firepot - Burning Softwood Pellets Every 5 bags OR X
Firepot - Burning Hardwood Pellets Every 3 bags OR X
Firepot - Burning Alternate Fuels Every 1 bag OR X
Glass When clear view of fi repot
becomes obscured
OR X
Heat Exchanger & Drop Tube Every 1 ton of fuel OR X
Hopper Every 1 ton of fuel or when chang-
ing fuel types
OR X
Venting System More frequently depending on the
fuel type
OR X